Rotary Viscometer
When the temperature deviation is 0.5°C, the deviation of the viscosity value of some liquids exceeds 5%, and the temperature deviation has a great influence on the viscosity. The temperature increases and the viscosity decreases. Therefore, special attention should be paid to keep the temperature of the liquid to be measured constant around the specified temperature point, and it is best not to exceed 0.1 °C for accurate measurement. For this reason, our company specializes in the production of constant temperature cups and constant temperature tanks to be used together with DHJ series viscometers.
- Description
- Specifications
- Paper
- Video
When the temperature deviation is 0.5°C, the deviation of the viscosity value of some liquids exceeds 5%, and the temperature deviation has a great influence on the viscosity. The temperature increases and the viscosity decreases. Therefore, special attention should be paid to keep the temperature of the liquid to be measured constant around the specified temperature point, and it is best not to exceed 0.1 °C for accurate measurement. For this reason, our company specializes in the production of constant temperature cups and constant temperature tanks to be used together with DHJ series viscometers.
Model | DHJ-8S |
Measuring range | 1 ~2×106mPa.s |
Rotor Specifications | Rotor No. 1-4 Optional No. 0 rotor can measure low viscosity to 0.1mPa.s |
Rotor speed | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm |
Measurement accuracy | ±2%(Newtonian liquid) |
Power supply | AC 220V±10% 50Hz±10% |
Working environment | Temperature 5℃~35℃, relative humidity not more than 80% |
Dimensions | 370×325×280mm |
Net weight | 6.8kg |
Model | DH-0506N |
Temperature range | -5~100(℃) |
Temperature fluctuation | ±0.05(°C) |
Temperature control method | Microcomputer temperature control, PID adjustment |
Display Resolution | 0.01(℃) |
Inner volume | 8(L) |
Inner groove size | 270×160×185(L×W×D)(mm) |
Opening size (diameter) | Φ75(mm) |
Pump circulation method | Inner/outer circulation |
Pump flow | 8(L) |
Refrigeration method | Compressor refrigeration |
Dimensions | 430×410×420(mm) |
host | 1 set + 1 set |
Rotors 1, 2, 3, 4 | 1 set (Note: No. 0 rotor is optional) |
Power Adapter | 1 set |
Protective frame | 1 single |
base | 1 single |
Lifting column | 1 set |
user's manual | 1 part |
certificate | 1 part |
Warranty | 1 part |
Hexagon head | 1 single |
dumb wrench | 2 single(Note: 1 for each size) |
Notes
1. The thermostatic bath should be placed on a solid workbench;
2. No vibration, no harmful gas;
3. The room temperature should be relatively stable, not high or low, otherwise it will affect the temperature control accuracy; the room temperature should be around 25℃, (especially -40℃, -65℃, -80℃ thermostat) It will affect the heat dissipation of the compressor, reduce the cooling efficiency, and easily cause failure;
4. The constant temperature bath should be maintained regularly, especially if the cooling speed is slowed down after working for a period of time, the plastic mesh plate of the constant temperature bath should be removed, and the dust of the compressor and heat sink should be removed.